The Battery Label Kit covers the battery side of a solar and storage install in one order. It suits a battery added to an existing solar system, a hybrid inverter with PV, or an AC-coupled battery with its own inverter.
The kit is built around its shutdown procedure. Every switch and isolator the procedure tells you to turn off has a matching label in the kit, worded exactly the same, so what is on the plate matches what is on the switchboard. The generic plate has fill-in lines for battery location, supplier and phone number, and includes a step for systems with backup.
The labels are designed around the battery and inverter signage requirements in AS/NZS 5139 and AS/NZS 4777.1. Engraved labels are laser-engraved Traffolyte, the danger sign and ES stickers are vinyl, and everything is backed with 3M adhesive. Made in Australia.
What's in the kit (27 labels):
2 x Battery Shutdown Procedure
2 x Warning: PV Array DC Isolators and Battery System Isolators Do Not De-energise
1 x Battery danger sign: Risk of Battery Explosion, Toxic Fumes, Restricted Access and PPE (175mm vinyl)
2 x ES UN3480 reflective sticker, 100mm
2 x Warning: Battery System DC Isolators Do Not De-energise
2 x BATTERY DC cable label, with fixing holes
1 x Battery Supply: short circuit current and max DC volts
1 x Battery System DC Isolator
1 x Battery Location
1 x Warning: Arc Flash Hazard
1 x Warning: Do Not Disconnect Under Load
1 x Warning: Multiple Battery Systems
1 x Multiple BESS Supplies
1 x Warning: Multiple Mode IES Connected
1 x Warning: Multiple Supplies
1 x Warning: Multiple Energy Sources
1 x Main Switch (Inverter)
1 x Inverter AC Isolator
1 x PV Array DC Isolator
1 x Main Switch (Alternative)
1 x Alternative Supply Circuits
1 x Warning: Alternative Supply Circuits Will Still Be Energised
Buying for a crew or several jobs? Volume pricing applies from 10 kits.